The dry steam sauna, also known as the dry sauna or dry steam room, is a type of sauna that uses dry heat to create a relaxing and detoxifying experience. dry heat sauna room,dry sauna,traditional sauna,dry heat sauna Foshan Nanhai Halo Sanitary Ware Co., Ltd. , https://www.halospas.com
**One: Insertion Force Test**
1. Set the movement mode to "two-way measurement" with a speed range of 1–300 (standard machine speed). The number of tests can be set from 1 to 10,000,000. Make sure to check the origin before starting the test.
2. Insert the male and female connectors of the tested product into the clamp. Ensure the clamp is vertical, and the automatic centering device is positioned near the center. Avoid any tilt to prevent damage or interference with the automatic centering function.
3. Zero the load and press the move button on the panel to separate the male and female ends slightly—do not fully remove them. Observe the display to ensure smooth movement.
4. Set the test stroke. Ideally, it should be 0.1–0.2 mm less than the actual stroke to avoid over-travel.
5. After setting all parameters, click "File" > "Pre-set Storage" to save the file. The filename must only include letters, numbers, periods, or hyphens—no spaces allowed.
6. Begin the test on the screen.
If the stroke is not detected, use a height gauge to measure the insertion stroke of the male plug. Adjust the position of the connectors and set the stroke accordingly. Ensure the set stroke does not exceed the measured value. The starting position is also crucial for accurate results.
**Two: Break Test**
1. Clamp the test product into the upper or lower fixture and adjust the height so that the product is securely held.
2. Set the mode to “Break Test.†The stroke should match the actual stroke of the product to allow full separation.
3. Set the speed and number of cycles, then save the file.
4. Return to zero and re-clamp the product. **Do not return to zero after clamping.**
5. Start the test.
**Three: PIN Test**
1. Connect the sensor interface to the test rod and lower the fixture. Adjust the position as needed.
2. Set the load measurement range to be higher than the force required to extract the PIN. The stroke measurement range should be less than the stroke above the insulation surface to avoid missing the actual force reading.
3. Select “Load Zero Position (only when force starts counting)†and save the settings.
4. Proceed with the test.
Alternatively, you can use “One-way Measurement†mode. In this case, the force curve will show only the downward motion without the return stroke.
**Four: Constant Pressure and Tensile Test**
1. Choose “Constant Pressure†mode. The software will automatically open the “Force†and “Time†data frames. Enter the desired force and time values and save the file.
2. Clamp the test product and adjust its position appropriately.
3. Start the test. When the set force is reached, timing begins and stops once the set time is completed.
For constant tensile testing, the process is similar, but there is no return stroke.
Note: These tests are slower, typically around 30 mm/min.
**Five: Longitudinal Force Test**
1. Select the load zero position and enable “Origin Detection Each Time.†Set the unit to “gram.â€
2. Connect the test rod to the corresponding test head.
3. Adjust the position and test the stress at different strokes.
Some customers require the stress value at the bottom point of the stroke. If needed, contact the after-sales technician for assistance with the micrometer.
**Six: Load-Displacement Test**
When testing how much deformation occurs under a specific force, or what force is required for a certain displacement, follow these steps:
1. Set the load range to the required force value and ensure the stroke is large enough.
2. Select the load zero position and enable “Origin Detection Each Time.â€
3. Set the speed (typically around 30 mm/min), number of tests, and save the file.
4. Perform the test. The maximum displacement on the waveform corresponds to the stroke you need to measure.
**Seven: Contact Resistance Test**
1. Configure the test settings as per the normal insertion force test.
2. Select the “Insertion Point Resistance Value†in the last column of the measurement items.
3. Clamp the male and female connectors using the impedance test fixture.
Other extended tests such as anti-bending, peel force, displacement-load, constant tensile life, and break force measurement can also be performed with the milligram brand insertion force testing machine. For detailed operation instructions, please call 15995758658 Wei Jia or email [email protected]. Note: These procedures apply only to the milligram brand insertion force testing machine with a patent certificate.
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn
The dry steam sauna is typically made of wood, with a small heater that heats up rocks or stones. These heated stones then radiate the heat into the sauna, creating a warm and dry environment.
The dry steam sauna is designed to promote sweating and detoxification. As the body heats up, the sweat glands are activated, helping to eliminate toxins and impurities from the body. This can have numerous health benefits, including improved circulation, increased metabolism, and enhanced immune system function.
In addition to its detoxifying properties, the dry steam sauna also offers relaxation and stress relief. The warm and dry environment can help to relax muscles, relieve tension, and promote a sense of calm and well-being. Many people find the dry steam sauna to be a great way to unwind and de-stress after a long day.
Insertion force test machine test example operation instructions
Example Operation Instructions for Insertion and Pull Force Testing Machine